CISQ Index

Extension ID

com.castsoftware.cisq-index

Description

This extension will compute CISQ Quality Software Characteristic Measures as Business Criteria and CISQ Measure Elements as Technical Criteria. All CAST rules that are tagged with a CISQ related tag will contribute to the various CISQ Measure Elements / CISQ Quality Software Characteristic Measures thereby allowing specific grades and rule violations to be reported.

Compatibility

Product Release Supported
CAST Imaging Core ≥ 8.3.24 ✔️
CAST Engineering Dashboard ≥ 1.5 ✔️
CAST Health Dashboard ≥ 1.17 ✔️
CAST Security Dashboard ≥ 1.18 ✔️

CISQ version

Version Supported
1.0 (December 2016) ✔️

Download and installation instructions

The extension will not be automatically downloaded and installed in CAST Imaging Console. If you need to use it, should manually install the extension.

Configuration requirements

Generate a snapshot

A new snapshot must be generated (after the extension is installed) before results can be viewed. If you do not immediately see changes in the dashboard, please consider restarting Apache Tomcat and/or emptying your browser cache.

Engineering Dashboard

Out of the box, no tiles will be provided to display data for this extension, however it is possible to create tiles manually to display Violation data using the Industry Standard/s tile plugin in v. ≥ 1.18 of the Engineering Dashboard. See Engineering Dashboard tile management for more information:

Clicking on the tile navigates to Risk investigation view and the specified Industry Standard will be selected in the Health Factor table.

Health Dashboard

Out of the box, no tiles will be provided to display data for this extension, however it is possible to create tiles manually to display Grade, Compliance, and Violation data directly from this extension using the Industry Standard/s tile plugin in v. ≥ 1.17 of the Health Dashboard. See Health Dashboard tile management for more information:

Clicking on any of these tiles will display a list of the rules that have been tagged with the specified standard as provided by the extension. Compliance percentage is also displayed in a “bubble”:

Compliance grade at Application level with compliance percentage displayed in a “bubble”

Compliance grade at Portfolio level

Example for cmp.json / cmp-ISO.json

Configuration to create a “gauge” tile at portfolio level (multi-app level) to show a “parent” CISQ-Security Business Criterion tile:

{
  "id": 1234,
  "plugin": "IndustryStandards",
  "color": "black",
  "parameters": {
    "type": "CISQ",
    "title": "CISQ-Security",
    "widget": "gauge",
    "industryStandard": {
        "id": "1062166",
        "indexID": "1062100",
        "mode": "grade",
        "format": "0.00",
        "description": "CISQ-Security in grade format"
    }
  }
}

Example for app.json

Configuration to create a “number of violations” tile at application level (single app level) to show a CISQ-Security Business Criterion tile:

{
  "id": 1236,
  "plugin": "IndustryStandard",
  "color": "orange",
  "parameters": {
    "type": "CISQ",    
    "title": "CISQ-Security",
    "industryStandard": {
        "id": "1062166",
        "indexID": "1062100",
        "mode": "violations",
        "format": "0,000",
        "description": "CISQ-Security in number of violations format" 
    }
  }
}

Security Dashboard

Out of the box, no tiles will be provided to display data for this extension, however it is possible to create tiles manually to display Violation data using the Industry Standard/s tile plugin in v. ≥ 1.18 of the Security Dashboard. The tile configuration is identical to that described for the Engineering Dashboard, see Engineering Dashboard tile management for more information:

Clicking on the tile navigates to Security Dashboard - Risk Investigation and the specified Industry Standard will be selected in the Health Factor table.

What results can you expect?

Once the analysis/snapshot generation has completed, you can view the results:

Assessment Model

Various Business and Technical Criteria will be added by the extension:

CISQ-Index

ID Name Type
1062100 CISQ-Index Business Criterion

Note that the CISQ-Index Business Criterion has all Technical Criteria listed below as contributors.

CISQ-Maintainability

ID Name Type
1062101 CISQ-Maintainability Business Criterion
1062110 ASCMM-MNT-1 Technical Criterion
1062121 ASCMM-MNT-2 Technical Criterion
1062123 ASCMM-MNT-3 Technical Criterion
1062124 ASCMM-MNT-4 Technical Criterion
1062125 ASCMM-MNT-5 Technical Criterion
1062126 ASCMM-MNT-6 Technical Criterion
1062127 ASCMM-MNT-7 Technical Criterion
1062128 ASCMM-MNT-8 Technical Criterion
1062129 ASCMM-MNT-9 Technical Criterion
1062111 ASCMM-MNT-10 Technical Criterion
1062112 ASCMM-MNT-11 Technical Criterion
1062113 ASCMM-MNT-12 Technical Criterion
1062114 ASCMM-MNT-13 Technical Criterion
1062115 ASCMM-MNT-14 Technical Criterion
1062116 ASCMM-MNT-15 Technical Criterion
1062117 ASCMM-MNT-16 Technical Criterion
1062118 ASCMM-MNT-17 Technical Criterion
1062119 ASCMM-MNT-18 Technical Criterion
1062120 ASCMM-MNT-19 Technical Criterion
1062122 ASCMM-MNT-20 Technical Criterion

CISQ-Performance-Efficiency

ID Name Type
1062102 CISQ-Performance-Efficiency Business Criterion
1062130 ASCPEM-PRF-1 Technical Criterion
1062137 ASCPEM-PRF-2 Technical Criterion
1062138 ASCPEM-PRF-3 Technical Criterion
1062139 ASCPEM-PRF-4 Technical Criterion
1062140 ASCPEM-PRF-5 Technical Criterion
1062141 ASCPEM-PRF-6 Technical Criterion
1062142 ASCPEM-PRF-7 Technical Criterion
1062143 ASCPEM-PRF-8 Technical Criterion
1062144 ASCPEM-PRF-9 Technical Criterion
1062131 ASCPEM-PRF-10 Technical Criterion
1062132 ASCPEM-PRF-11 Technical Criterion
1062133 ASCPEM-PRF-12 Technical Criterion
1062134 ASCPEM-PRF-13 Technical Criterion
1062135 ASCPEM-PRF-14 Technical Criterion
1062136 ASCPEM-PRF-15 Technical Criterion

CISQ-Reliability

ID Name Type
1062103 CISQ-Reliability Business Criterion
1062145 ASCRM-CWE-120 Technical Criterion
1062146 ASCRM-CWE-252-data Technical Criterion
1062147 ASCRM-CWE-252-resource Technical Criterion
1062148 ASCRM-CWE-396 Technical Criterion
1062149 ASCRM-CWE-397 Technical Criterion
1062150 ASCRM-CWE-456 Technical Criterion
1062151 ASCRM-CWE-674 Technical Criterion
1062152 ASCRM-CWE-704 Technical Criterion
1062153 ASCRM-CWE-772 Technical Criterion
1062154 ASCRM-CWE-788 Technical Criterion
1062155 ASCRM-RLB-1 Technical Criterion
1062166 ASCRM-RLB-2 Technical Criterion
1062167 ASCRM-RLB-3 Technical Criterion
1062168 ASCRM-RLB-4 Technical Criterion
1062169 ASCRM-RLB-5 Technical Criterion
1062170 ASCRM-RLB-6 Technical Criterion
1062171 ASCRM-RLB-7 Technical Criterion
1062172 ASCRM-RLB-8 Technical Criterion
1062173 ASCRM-RLB-9 Technical Criterion
1062156 ASCRM-RLB-10 Technical Criterion
1062157 ASCRM-RLB-11 Technical Criterion
1062158 ASCRM-RLB-12 Technical Criterion
1062159 ASCRM-RLB-13 Technical Criterion
1062160 ASCRM-RLB-14 Technical Criterion
1062161 ASCRM-RLB-15 Technical Criterion
1062162 ASCRM-RLB-16 Technical Criterion
1062163 ASCRM-RLB-17 Technical Criterion
1062164 ASCRM-RLB-18 Technical Criterion
1062165 ASCRM-RLB-19 Technical Criterion

CISQ-Security

ID Name Type
1062166 CISQ-Security Business Criterion
1062177 ASCSM-CWE-22 Technical Criterion
1062189 ASCSM-CWE-78 Technical Criterion
1062191 ASCSM-CWE-79 Technical Criterion
1062194 ASCSM-CWE-89 Technical Criterion
1062195 ASCSM-CWE-99 Technical Criterion
1062174 ASCSM-CWE-120 Technical Criterion
1062175 ASCSM-CWE-129 Technical Criterion
1062176 ASCSM-CWE-134 Technical Criterion
1062178 ASCSM-CWE-252-resource Technical Criterion
1062179 ASCSM-CWE-327 Technical Criterion
1062180 ASCSM-CWE-396 Technical Criterion
1062181 ASCSM-CWE-397 Technical Criterion
1062182 ASCSM-CWE-434 Technical Criterion
1062183 ASCSM-CWE-456 Technical Criterion
1062184 ASCSM-CWE-606 Technical Criterion
1062185 ASCSM-CWE-667 Technical Criterion
1062186 ASCSM-CWE-672 Technical Criterion
1062187 ASCSM-CWE-681 Technical Criterion
1062188 ASCSM-CWE-772 Technical Criterion
1062190 ASCSM-CWE-789 Technical Criterion
1062192 ASCSM-CWE-798 Technical Criterion
1062193 ASCSM-CWE-835 Technical Criterion

Engineering Dashboard

In ≥ 1.18.0 out of the box, results are displayed in a specific interface - click the CISQ Assessment Model option to view the results:

Health Dashboard

Out of the box, no results are provided. Tiles can be configured manually as described above.

Security Dashboard

Out of the box, results are displayed in a specific interface - click the CISQ Assessment Model option (after clicking the Risk Investigation tile in the Application home page) to view the results:

Only the CISQ-Security Business Criterion will be available (due to the default filtering implemented in the Security Dashboard):

RestAPI